X-Ray Room Lead Lining and Shielding

Site survey, shielding plan, lead lining, door and leaded glass for your X-ray room. The institution operating the device receives the NDK licence; we deliver the project and the device documents.

Lead-lined X-ray room with a lead glass control window

Is lead lining mandatory in an X-ray room?

Yes. Every room where an X-ray device is installed is prepared to the rules of the NDK (Nuclear Regulatory Authority), whatever the mA rating of the device, and the device needs an NDK licence (RG 20.01.2022 / 31725, art. 8/4). In practice this means the walls, ceiling, floor and door are lined with lead according to the shielding calculation.

The thickness is not a standard number; it is calculated. The site survey and the shielding plan are the steps that should start before the device is ordered. Last updated: 11.11.2026. This information is for guidance only, as of 11.11.2026.

How is an X-ray room lead-lined?

Inside a lead-lined X-ray room, X-ray tube on its stand and wall panels
  1. 1

    Site survey

    The room dimensions, the adjacent areas and the device data are collected.

  2. 2

    Shielding plan

    The shielding calculation is made from the device power, the workload and the adjacent areas, and the plan is drawn.

  3. 3

    Lead sheet

    Lead sheet of the thickness in the plan is applied to the walls, ceiling and floor.

  4. 4

    Door and glass

    The leaded radiation door and the leaded glass are fitted.

  5. 5

    Handover

    The shielding plan and the device documents are delivered as a file.

Fixed Installation

Permanent lead-panel application in a rented or owned office or clinic space.

Container X-Ray Room

ISO container lined according to the shielding calculation; lockable and relocatable.

Prefabricated Module

Factory-built ready-made module; assembled on site and can be repositioned when needed.

How many mm of lead are needed?

No fixed number sets the thickness: the device power, the workload, the adjacent areas and the use of the room come together in one shielding calculation. Dentem applies 1 to 3 mm of sheet according to the project. This range is Dentem's practice, not a value written in the regulation.

X-ray room door and leaded glass

The door and the glass are part of the same shielding calculation as the walls. Dentem makes and fits custom-made lead-lined radiation doors, and also applies leaded glass.

Who receives the NDK licence?

The institution operating the device files the application (RG 28.10.2023 / 32353, art. 11/2). Dentem takes on the site survey, the shielding plan and the installation, and delivers the project and device documents the application needs.

Source: Regulation on Authorisations Concerning Radiation Facilities and Radiation Practices, Official Gazette 28.10.2023, No. 32353. Last updated: 11.11.2026. This information is for guidance only, as of 11.11.2026.

Which facilities is it suitable for?

OSGB fixed screening units
Hospital radiology departments
Dental clinics
Veterinary clinics
Mobile health vehicles (in-vehicle shielding)

What determines the price of lead lining for an X-ray room?

There is no single figure; the quote is given item by item after the site survey. The price is set by:

  • Room size (m²)
  • Device power and workload
  • Lead sheet thickness
  • Number and size of doors and glass
  • Type of work: fixed installation, container or prefabricated module
  • Project scope
Request a Free Site Survey

For a product summary see the lead-lined X-ray room page.

Frequently Asked Questions

How many mm of lead does an X-ray room need?

The thickness is not a fixed number; it is set by a shielding calculation based on the device power, the workload, the adjacent areas and the way the room is used. The work moves from the site survey to the plan, then lead sheet on the walls, a leaded door and leaded glass. Dentem applies 1 to 3 mm of sheet according to the project; this range is Dentem's practice, not a value written in the regulation. The institution operating the device files the NDK application; we deliver the project and the device documents.

Who receives the NDK licence for an X-ray device?

The natural or legal person operating the device files the application (Regulation on Authorisations Concerning Radiation Facilities and Radiation Practices, RG 28.10.2023 / 32353, art. 11/2). Dentem delivers the technical information of the device and, where needed, the shielding plan. This information is for guidance only, as of 11.11.2026.

Want to Get a Quote or More Information?

Reach us on WhatsApp or by phone. The 24/7 fault line takes your call.