A modular screening unit that can be set up in rented or existing office space. The X-ray room follows an NDK shielding plan; the OSGB files the permit, and we guide you on devices and documents.

Fixed medical screening unit built inside an industrial facility

What is a fixed screening unit, and who can set one up?

A fixed screening unit is a permanent site where employee health surveillance tests are done at one address: a separate X-ray room, an audiometry booth, and spirometry, ECG and eye examination devices are gathered there. An OSGB, a ÇASMER or the workplace's own occupational health and safety unit (İSGB) can run the tests.

The unit needs a separate permit for the tests, and each test is listed separately in that permit (RG 20.01.2022 / 31725, art. 5). A mobile vehicle is only for OSGBs and ÇASMERs; an İSGB can only set up a fixed unit.

Who files the permit application?

The OSGB receives the permit; the institution operating the device receives the NDK licence. For a workplace's own unit, the İSGB files the application, and it is filed with the provincial health directorate (RG 31725, art. 16). Dentem prepares the device information and documents and explains which document goes where.

Source: Regulation on the Procedures and Principles of Medical Tests for Employee Health Surveillance, Official Gazette 20.01.2022, No. 31725. Last updated: 11.11.2026. This information is for guidance only, as of 11.11.2026.

Requirements for the space

X-ray room

X-ray equipment is installed in a separate room built to NDK rules, and every X-ray device needs an NDK licence (art. 8/3-4).

Dentem: lead-lined X-ray room, from the site survey to the shielding plan and installation.

Audiometry area

Hearing tests are done in a quiet booth; the booth, staff and device area must together be at least 4 m² (art. 10).

Dentem: audiometry booth installation, with the layout fitted to the space.

If you are setting up an in-plant occupational health and safety unit (İSGB)

A workplace's own occupational health and safety unit can do the tests only in a fixed screening unit; it cannot use a mobile vehicle. We set up the layout and the device set according to the workplace's test list: whichever tests will be done, those rooms and those devices come.

The İSGB files the permit application. Dentem installs the devices and the lead-lined room, trains your team and provides the device documents the application needs.

What Dentem installs

Dentem

  • Planning the layout of the space
  • Lead-lined X-ray room: site survey, shielding plan, installation
  • Installation of the X-ray device and digital detector
  • Installation of the audiometry booth and audiometer, and of the spirometry, ECG, eye and laboratory devices
  • Device training for your team
  • Handover file: ÜTS registration details of the devices, technical files, X-ray device information for the NDK application
  • Explaining which document goes where in the application
  • After-sales service

Device set

Spirometry and ECG examination area in a fixed screening unit
Device set by test
Test Device
X-ray (PA chest radiograph) Amadeo digital X-ray, iRay digital detector
Audiometry Amadeo audiometry booth, Maico or GSI audiometer
Pulmonary function test (SFT) MIR Minispir spirometer
ECG Zoncare iMAC ECG devices
Eye examination Autorefractometer and eye examination devices
Blood count and blood test Zybio Z3 haematology analyser

Process

  1. 1

    Site survey

    The space, the tests to be done and the number of employees to be screened per day are settled.

  2. 2

    Layout plan

    The X-ray room, the audiometry area and the other rooms are written into the plan.

  3. 3

    Shielding and room

    The shielding plan of the X-ray room is drawn and carried out.

  4. 4

    Device installation

    The devices are installed in the rooms and put into operation.

  5. 5

    Training

    Your team is trained in using the devices.

  6. 6

    Handover file

    Documents and registration details are delivered as a file.

We have worked in radiology devices since 1994. The ÜTS registration details of the devices are in the handover file.

Frequently Asked Questions

Which devices are needed for tests at an OSGB?

Tests are done in a mobile occupational health vehicle or in a fixed medical screening unit, and each test is listed separately in the permit (RG 20.01.2022 / 31725, art. 5). The devices are: an X-ray device and digital detector for the PA chest radiograph, a quiet booth and audiometer for audiometry, a spirometer for the pulmonary function test, an ECG device, eye examination devices, and sampling and basic laboratory equipment. Dentem delivers these devices installed and your team trained. This information is for guidance only, as of 11.11.2026.

Can a factory's own occupational health and safety unit use a mobile vehicle?

No. The workplace's own unit (İSGB) can do the tests only in a fixed medical screening unit; the mobile vehicle is for OSGBs and ÇASMERs (RG 20.01.2022 / 31725, art. 5). The X-ray is installed in a separate room built to NDK rules; for audiometry, the booth, staff and device area must be at least 4 m² in total (art. 8, 10). The İSGB files the permit application; Dentem installs the devices and the lead-lined room and trains your team. This information is for guidance only, as of 11.11.2026.